Samples / GLPI-103 / regulatory/m5-clinical/clin-pharm/BIOANALYTICAL-001_bioanalytical_method_validation.md

Bioanalytical Method Validation Summary — GLPI-103 (PK Assay & Anti-Drug-Antibody Assay)

Field Value
Document ID BIOANALYTICAL-001
Version 1.0
Status Final
Compound GLPI-103 (GLP-1 / Apelin [APJ] receptor dual agonist)
Sponsor Virtual Biopharma Inc.
CTD location Module 5.3.1.4 / 2.7.1 — Bioanalytical & analytical methods
Standard(s) ICH M10 (Bioanalytical Method Validation); FDA/EMA BMV guidance
Confidentiality Confidential — portfolio use

[MOCK — deep-knowledge assumption] No bioanalytical dataset is simulated. Validation parameters are illustrative and consistent with ICH M10 acceptance criteria for a peptide LC–MS/MS assay and a ligand-binding ADA assay. This document stands in for the full method-validation reports a real submission would file, and supports the PK (CLINPHARM-002) and immunogenicity (IMMUNO-001) analyses.

Change History

Version Date Author Summary of Change
1.0 2026-07-05 Bioanalytical Initial submission-grade summary of PK-assay and ADA-assay validation

Abbreviations

ADA anti-drug antibody · CV coefficient of variation · ISR incurred-sample reanalysis · LC–MS/MS liquid chromatography–tandem mass spectrometry · LLOQ lower limit of quantification · MRD minimum required dilution · QC quality control · ULOQ upper limit of quantification.


1. Scope

Two validated methods underpin the clinical-pharmacology and immunogenicity programs: (1) a quantitative LC–MS/MS assay for GLPI-103 in human plasma (PK), and (2) a tiered ligand-binding ADA assay (screening/confirmatory/titre/neutralizing). Both were validated to ICH M10 prior to sample analysis and monitored by in-study QC and, for the PK assay, incurred-sample reanalysis.

2. PK Assay — LC–MS/MS (human plasma) [MOCK]

Validation parameter Result ICH M10 acceptance
Analyte / internal standard GLPI-103 / stable-isotope-labelled GLPI-103 —
Calibration range (LLOQ–ULOQ) linear over the clinical range ≥ 75% calibrators within ±15% (±20% at LLOQ)
Accuracy (QC, inter-run) within ±15% of nominal (±20% at LLOQ) ±15% / ±20%
Precision (QC, inter-run CV) ≤ 15% (≤ 20% at LLOQ) ≤ 15% / ≤ 20%
Selectivity / specificity no interference from matrix, metabolites, or co-medications (metformin, semaglutide) met
Matrix effect / recovery consistent, reproducible met
Stability bench-top, freeze–thaw, long-term frozen, autosampler — all covered met
Dilution integrity validated for above-ULOQ samples met
Incurred-sample reanalysis (ISR) ≥ 2/3 of samples within 20% ≥ 67% within 20%

The PK assay met all ICH M10 criteria and was fit for purpose for the pharmacokinetic analyses (CLINPHARM-002).

3. Anti-Drug-Antibody Assay — tiered ligand-binding [MOCK]

Validation parameter Result Basis
Format bridging electrochemiluminescence immunoassay —
Screening cut point statistically determined (target ~5% false-positive) FDA/EMA immunogenicity guidance
Confirmatory cut point competitive inhibition with excess drug (~1% false-positive) —
Sensitivity low-ng/mL surrogate positive control fit-for-purpose
Drug tolerance adequate at anticipated trough drug concentrations —
Minimum required dilution (MRD) established —
Titre & neutralizing (NAb) serial-dilution titre; competitive ligand-binding NAb characterization tiers
Selectivity / matrix no relevant interference —

The tiered ADA method met fit-for-purpose validation criteria and supported the integrated immunogenicity assessment (IMMUNO-001), including drug-tolerance adequate to interpret on-treatment samples and a NAb assay to characterize positive samples.

4. Conclusion

Both bioanalytical methods were validated to ICH M10 and monitored during sample analysis (in-study QC; PK ISR), establishing that the pharmacokinetic and immunogenicity conclusions rest on analytically sound data. Method details and validation are cross-referenced from Module 2.7.1 and the individual PK/immunogenicity reports.

5. References

ICH M10; FDA/EMA bioanalytical and immunogenicity guidance; CLINPHARM-002 (PK); IMMUNO-001 (immunogenicity); M2.7.1.